1. INTRODUCTION

Storage systems have been confounding database administrators and designers since Microsoft first released SQL Server. Today DBAs are not only required to design and maintain SQL Server, but are also often pressed into service as storage administrators. For DBAs working in the enterprise, communication with the server, networking, and especially storage teams are always a challenge.

By examining various storage hardware components, you will learn how best to protect your data with RAID technology. You will also see how storage area networks assist in data protection. Finally, you will learn how to validate your functional configuration and performance.

2. SQL SERVER I/O

Let’s begin by investigating how SQL Server generates I/O. We are concerned with reading existing data and writing new data. At its most basic SQL Server is made up of a few files that reside within the server file system. As a rule, different computer system components perform at different rates. It is always faster to process items in the CPU than it is to serve requests from processor cache.

SQL attempts to mitigate the relatively slow I/O system by caching whatever it can in system memory. Newly received data is first written to the SQL transaction log by SQL Server write-ahead logging (WAL). The data is then written to buffer pages hosted in server memory. This process ensures that the database can be recovered in the event of failure.

Contrast these write operations with read requests that are generated by SQL Server worker threads. The workers initiate I/O read operations using the SQL Server asynchronous I/O engine. By utilizing an asynchronous operation worker threads can perform other tasks while the read request is completed. The asynchronous I/O engine depends on Windows and the underlying storage systems to successfully read and write data to permanent storage.

SQL Server takes advantage of the WriteFileGather and ReadFileScatter Win32 APIs. WriteFileGather collects data from discontinuous buffers and writes this data to disk. ReadFileScatter reads data from a file and disperses data into multiple discontinuous buffers. These scatter/gather APIs allow the bundling of potential I/O operations thus reducing the actual number of physical read and write operation.

3. STORAGE TECHNOLOGY

The Host Bus Adapter (HBA) handles connections from the server to storage devices and can also perform several other roles. While a basic HBA provides connectivity to storage, more advanced HBAs have embedded Array controllers. When the storage is located within or attached to the server, it is called Direct Attached Storage (DAS). A storage device managed by a dedicated external array controller is called Storage Area Network (SAN) attached storage. Figure 1 shows the basic building blocks of a storage subsystem.

FIGURE 1

image

Storage devices connected to a storage network that are not logically grouped are called, rather inelegantly, a JBOD, for “just a bunch of disks (or drives).” Figure 2 shows an example of a JBOD. JBODs can be accessed directly by SQL Server as individual physical disk drives. Just remember that JBODs do not offer any protection against failure.

FIGURE 2

image

Storage array controllers group disks into volumes called a redundant array of inexpensive disks (RAID). RAID-constructed volumes offer capacity without failure protection. The simplest type of unprotected RAID set is often called disk striping, or RAID 0.

To understand a RAID 0 set, imagine a series of four disk drives lined up in a row. Data written to a stripe set will fill the first drive with a small amount of data. Each subsequent drive will then be filled with the same amount of data, at which point the process is repeated starting with the first disk drive. Figure 3 shows how data looks after it has been written to a RAID 0 disk subsystem. Each data stripe is made up of some uniform data size. Most RAID systems allow the user to modify the size of the data stripe.

FIGURE 3

image

Concatenated disk arrays are similar to stripe datasets, differing in the method used to load data. You can think of concatenated datasets as a group of disk drives that are filled in series. The first group is filled, then the second group, and so on.

Figure 4 shows the contrast between striped RAID, which is serpentine in its layout, and the waterfall pattern of a concatenated disk array. Concatenated systems don’t necessarily lack data protection. Many storage arrays layer different types of RAID. One example is a system that combines mirrored physical disks into a concatenated RAID set. This combined system offers the benefits of protected data and the ease of adding more capacity on demand since each new concatenated mirror will be appended to the end of the overall RAID set.

FIGURE 4

image

RAID defines two ways to provide failure protection: disk mirroring and parity generation. RAID 1, often called disk mirroring, places data in equal parts on separate physical disks. If one disk fails, the array controller will mirror data from the remaining good disk onto a new replacement disk. Figure 5 details the frequent combination of mirroring and striping. This system is often called RAID 1 + 0 or simply RAID 10.

FIGURE 5

image

The storage array uses an exclusive or (XOR) mathematical calculation to generate parity data. Parity enables the array to recreate missing data by combining parity information with the data that is distributed across the remaining disks. This parity data enables you to make efficient use of your capacity but at the cost of performance, as the XOR calculation needed to generate the parity data is resource intensive.

Many different parity RAID configurations have been defined. The two most common types are disk striping with parity (RAID 5) and disk striping with double parity (RAID 6). Examples of both are shown in Figure 6 and Figure 7. RAID 5 protects a system against a single disk drive failure. RAID 6 protects against a double disk failure. RAID 5 and 6 offer disk failure protection while minimizing the amount of capacity dedicated to protection. Contrast this with RAID 1, which consumes half of the available storage in order to protect the data set.

FIGURE 6

image

FIGURE 7

image

To create the parity information the RAID engine reads data from the data disks. This data is computed into parity by the XOR calculation. The parity information is written to the next data drive. The parity information is shifted to a different drive with each subsequent stripe calculation thus ensuring no single drive failure causes catastrophic data loss.

RAID 6 generates two parity chunks and diversifies each across a different physical disk. This double parity system protects against a double disk drive fault. As disk drives become larger and larger, there is a significant chance that before the failed data can be repaired a second failure will occur.

RAID 5 and RAID 6 become more space efficient on larger sets of disk drives. A RAID 5 disk set using seven data drives and one parity drive will consume less relative space than a disk set using three data drives and one parity drive.

Each of these RAID sets represents a failure domain. That is to say, failures within the domain affect the entire dataset hosted by a given failure domain. Large failure domains can also incur a performance penalty when calculating the parity bits. In a four-disk RAID 5 set, only three data drives are accessed for parity calculation. Given an eight-disk RAID set, seven drives are accessed.

You can combine RAID types into the same volume. Striping or concatenating several RAID 5 disk sets enables the use of smaller failure domains while increasing the potential size of a given volume. A striped, mirrored volume is called RAID 1+0 (or simply RAID 10). This RAID construct can perform extremely well at the cost of available capacity.

Many storage controllers monitor how RAID sets are accessed. Using a RAID 10 dataset as an example, several read requests sent to a given mirrored drive pair will be serviced by the drive with the least pending work. This work-based access enables RAID sets to perform reads more rapidly than writes.

Other  
 
Top 10
Free Mobile And Desktop Apps For Accessing Restricted Websites
MASERATI QUATTROPORTE; DIESEL : Lure of Italian limos
TOYOTA CAMRY 2; 2.5 : Camry now more comely
KIA SORENTO 2.2CRDi : Fuel-sipping slugger
How To Setup, Password Protect & Encrypt Wireless Internet Connection
Emulate And Run iPad Apps On Windows, Mac OS X & Linux With iPadian
Backup & Restore Game Progress From Any Game With SaveGameProgress
Generate A Facebook Timeline Cover Using A Free App
New App for Women ‘Remix’ Offers Fashion Advice & Style Tips
SG50 Ferrari F12berlinetta : Prancing Horse for Lion City's 50th
- Messages forwarded by Outlook rule go nowhere
- Create and Deploy Windows 7 Image
- How do I check to see if my exchange 2003 is an open relay? (not using a open relay tester tool online, but on the console)
- Creating and using an unencrypted cookie in ASP.NET
- Directories
- Poor Performance on Sharepoint 2010 Server
- SBS 2008 ~ The e-mail alias already exists...
- Public to Private IP - DNS Changes
- Send Email from Winform application
- How to create a .mdb file from ms sql server database.......
programming4us programming4us
programming4us
 
 
programming4us